KK Series

KK-250S(250gx 1 container)

2 axis KK-250S
KK-250SECE
(250g x 1 container)

Learn morezoom_in
KK-300SS(310gx 1 container)

1 axis KK-300SS
KK-300SSECE
(310g x 1 container)

Learn morezoom_in
KK-400W(400g x 2 container)KK-400WE

2 axis KK-400W
KK-400WECE
(400g x 2 container)

Learn morezoom_in
KK-1000WE(1kg x 2 container)

2 axis KK-1000WECE
(1kg x 2 container)

Learn morezoom_in
KK-2000WE(2kg x 2 container)

2 axis KK-2000WE
(2kg x 2 container)

Learn morezoom_in
KK-5000W/KK-5000WE(5kg x 2 container)

2 axis KK-5000W
KK-5000WECE
(5kg x 2 container)

Learn morezoom_in
KK-10000(10kg x 2 container)

1 axis KK-10000
(10kg x 2 container)

Learn morezoom_in

2 axis
Revolution / Rotation independent change

Revolution / Rotation independent change

1 axis
Fixed ratio of Revolution / Rotation

Fixed ratio of Revolution / Rotation

Major Features

容器オプション

By rotating the container containing the material while orbiting it, mixing and defoaming are performed simultaneously in a short time without using a stirring rod or vacuum equipment. The ratio of rotation and revolution can be changed to set the optimum mixing and defoaming for materials with large differences in specific gravity.

MAZERUSTAR can show you a great performance for the following materials and purposes.

  • High viscosity liquids that cannot be handled by conventional equipment, or that take a long time to process.
  • Liquids or liquids with powders or fillers which has a large difference of specific gravity.
  • Materials required to be processed without waste and contamination. Processes that require less cleaning of equipment and containers.

MAZERUSTAR has 2 unique mechanisms to provide the best performance.

Point 1.

Independently variable revolution /rotation speed ratio (except for some models).

Point 2.

Variable motion continuous step mechanism (up to 5 steps).

Major Applications

MAZERUSTAR is often used in the following applications.

  • High viscosity liquids that cannot be handled by conventional equipment, or that take a long time to process.
  • Liquids or liquids with powders or fillers which has a large difference of specific gravity.
  • Materials required to be processed without waste and contamination. Processes that require less cleaning of equipment and containers.

Silver Powders: 30 / Resins: 20 / Hardener: 5

><Silver Pastes> Silver Powders: 30 / Resins: 20 / Hardener: 5
Model KK-250S
KK-250SE
KK-300SS
KK-300SSE
KK-400W
KK-400WE
Standard Container(*1) HDPE
250mL Standard Container
HDPE
300mL Standard Container
HDPE
370mL Standard Container
Maximum Processing Amount(*2) 250gx1 container 310gx1 container 400gx2 container
Revolution 10 level variable (10-1) 10 rpm
(Fixed ratio of rotation / revolution)
*Mixing, medium, degassing, and wave mode are selectable
10 level variable (10-1)
Rotation 10 level variable(9-0)
(0.0-1.0 times of revolution speed)
10 level variable(9-0)
(0.0-0.91 times of revolution speed)
Setting Time 10-990 seconds × 5 steps
*Max. total operation time: 990 seconds (Units od 10 sec.)
*Max. operation time: 990 seconds
0 second - 30 minutes × 9 steps
*Max total operation time: 30 minutes
10-990 seconds × 5 steps
*Max. total operation time: 990 seconds (Units od 10 sec.)
*Max. operation time: 990 seconds
Channels 100(Fixed Channels:10、
User Setting Channels:90)
User Setting Channels:10 100(Fixed Channels:10、
User Setting Channels:90)
Alarm Function Unbalance, Top cover and maintenance cover open, Overload
Safety Function Automatic stop when error occurs, Door lock during operation, Operation prohibited when the top cover is opened
Temperature and Himidity for use 10~40℃、20~80%RH(No dew condensation)
Power Supply (S)AC100V±10%
(SE)AC200~240V
(SS)AC100V±10%
(SSE)AC200~240V
(W)AC100V±10%
(WE)AC200~240V
Power Consumption Approx.650W Approx.400W Approx.750W
Monitoring Function
(*3)
Dimension
(WxDxH)
350x420x415 mm 340x315x370 mm 400x513x457 mm
Main Body Weight 37㎏ 24㎏ 51㎏
Model KK-1000WE KK-2000WE KK-5000W
KK-5000WE
Standard Container(*1) HDPE
1.1L Standard Container
Max. Approx.2L
(customer's designated containers are available with adapter)
HDPE
3.5L Standard Container
Maximum Processing Amount(*2) 1㎏x2 container 2㎏x2 container 5㎏x2 container
Revolution 10 level variable (10-1) 9 level variable(9-1)
Rotation 10 level variable(9-0)
0.0-0.94 times of revolution speed
10 level variable(9-0)
0.0-1.0 times of revolution speed
Setting Time 0 second - 990 seconds × 5 steps
*Max. operation time: 990 seconds
10-900 seconds × 5 steps
*Max total operation time: 25 minutes
10-300 seconds
*Max total operation time: 25 minutes
Channels 100(Fixed Channels:10、User Setting Channels:90)
Alarm Function Unbalance, Top cover and maintenance cover open, Overload
Safety Function Automatic stop when error occurs, Door lock during operation, Operation prohibited when the top cover is opened
Temperature and Himidity for use 10~40℃、20~80%RH(No dew condensation)
Power Supply 1φ、AC200V±10% 3φ、AC200V±5% (W)3φ、AC200V~240V
(WE)3φ、AC380~415V
Power Consumption Approx.2kW Approx.2.5kW Approx.7kW
Monitoring Function
(*3)
Dimension
(WxDxH)
565x597x700 mm 646x663x851 mm 790x910x1091 mm
Main Body Weight Approx.140kg Approx.225㎏

Approx.475㎏

Model KK-10000
Standard Container(*1) HDPE 4L Standard Container
Maximum Processing Amount(*2) 10㎏x2 container
Revolution 9 level variable(9-1)
(Fixed ratio of rotation / revolution)
Rotation
Setting Time 10-300 seconds × 3 steps
Channels 20(Fixed Channels:10、User Setting Channels:10)
Alarm Function Unbalance, Top cover and maintenance cover open, Overload
Safety Function Automatic stop when error occurs, Door lock during operation, Operation prohibited when the top cover is opened
Temperature and Himidity for use 10~40℃、20~80%RH(No dew condensation)
Power Supply 3φ、AC200V±5%
Power Consumption Approx.10kW
Monitoring Function
(*3)
-
Dimension
(WxDxH)
950x1070x1224 mm
Main Body Weight Approx.600㎏

 * Specifications may change without prior notice
(*1)Multiple containers and syringes can be used with an adapter (optional).
(*2)Gross weight including container and adapter. Processing weight may be less depending on operating conditions and the nature of the sample.
(*3)Temperature sensor unit is optional.