KKV Series

KK-V300SS(310g×1 container)

1 axis KK-V300SS
(310g x 1 container)

Learn morezoom_in
KK-V350WE(350g×2 containers)

2 axis KK-V350WECE
(350g x 2 containers)

Learn morezoom_in
KK-V1000W(1kg × 2 containers)

2 axis KK-V1000W
(1kg x 2 containers)

Learn morezoom_in
KK-V3500(3.5kg×2 containers)

2 axis KK-V3500
(3.5kg x 2 containers)

Learn morezoom_in

2 axis
Revolution / Rotation independent change

Revolution / Rotation independent change

1 axis
Fixed ratio of Revolution / Rotation

Fixed ratio of Revolution / Rotation

Major Features

Major Features

Twist
[2-cup eccentric system]・・・KK-V350W (option)
Increased contact surface and friction speed between the material and the inner wall of the container increases mixing and dispersion power.

Various vacuum setting parameters

The vacuum can be controlled by monitoring the degree of depressurization, contributing to improved quality control through highly reproducible vacuum control, and providing an optimal defoaming process for various materials.

Ample vacuum decompression capacity

High-performance vacuum pumps are used to achieve a vacuum attainment of 100 Pa and a high-speed vacuum attainment of 2 minutes to 100 Pa.

Reliable Vacuum Control

A magnetic fluidic seal developed by NASA minimizes the burden on the equipment due to vacuuming and achieves a durability equivalent to that of conventional machines.

Vacuum mechanism

High effective vacuum

Reliable vacuum control

Safety design of motor and electrical systems

Vacuum mechanism
Model KK-V300SS(TYPE-Ⅰ) KK-V300SS(TYPE-Ⅱ)
Standard Container(*1) HDPE 300mL Standard Container
Maximum Processing Amount(*2) 310g×1 container
Revolution 9 levels (9-1)
Rotation 0.5 times of revolution speed 1.0 times of revolution speed
Setting Time 10-300 seconds × 5 steps
*Max total operation time: 25 minutes
Number of Channel 100 (fixed channel: 10,
user setting channel: 90)
Vacuum System Pump Ultimate pressure: 200Pa
Pumping speed: 133L/160L/ min (50/60Hz)
Chamber Independent chamber with reduced pressure only in the vessel rotation area
Settings Set vacuum degree kPa voluntarily for each step
Alarm Function Unbalance, Upper lid and /or maintenance cover open, and overload
Safety Function Automatic shutoff in case any error, locking the door while operation and preventing the system from while the door open
Temperature and Humidity for use 10-40℃, 20-80%RH (No dew condensation)
Power Supply AC100V±10%
Power Consumption Approx.1.5kW
Monitoring Function
(*3)
Dimension 685×602×490 mm
Main Body Weight Approx.103kg
Model KK-V350WE
Standard Container(*1) HDPE 370mL Standard Container
Maximum Processing Amount(*2) 350g×2 containers
Revolution 9 levels (9-1)
Rotation 10 levels (9-0)
(0.0-1.0 times of revolution speed)
Setting Time 10-300 seconds × 5 steps
*Max total operation time: 25 minutes
Number of Channel 100 (fixed channel: 10,
user setting channel: 90)
Vacuum System Pump Ultimate pressure: 100Pa
Pumping speed: 100L/120L/ min (50/60Hz)
Chamber Independent chamber with reduced pressure only in the vessel rotation area
Settings Set vacuum degree kPa voluntarily for each step
Alarm Function Unbalance, Upper lid and /or maintenance cover open, and overload
Safety Function Automatic shutoff in case any error, locking the door while operation and preventing the system from while the door open
Temperature and Humidity for use 10-40℃, 20-80%RH (No dew condensation)
Power Supply AC200~240V
Power Consumption Approx.2.0kW
Monitoring Function
(*3)
Dimension 565×682×725 mm
Main Body Weight Approx.160kg(vacuum pump is not included)
Model KK-V1000W
Standard Container(*1) HDPE 1.1L Standard Container
Maximum Processing Amount(*2) 1kg × 2 containers
Revolution 9 levels (9-1)
Rotation 10 levels (9-0)
(0.0-0.94 times of revolution speed)
(Limited by the level of revolution)
Setting Time 10-300 seconds × 5 steps(*3)
Number of Channel 100 (fixed channel: 10,
user setting channel: 90)
Vacuum System Pump Ultimate pressure: 6.7Pa
Pumping speed: 200L/240L/ min (50/60Hz)
Chamber Independent chamber with reduced pressure only in the vessel rotation area
Settings Set vacuum degree kPa voluntarily for each step
Alarm Function Unbalance, Upper lid and /or maintenance cover open, and overload
Safety Function Automatic shutoff in case any error, locking the door while operation and preventing the system from while the door open
Temperature and Humidity for use 10-40℃, 20-80%RH (No dew condensation)
Power Supply 3φ、AC200V±10%
Power Consumption Approx.3.0kW
Monitoring Function
(*3)
Dimension 761×784×822 mm
Main Body Weight Approx.260kg(vacuum pump is not included)
Model KK-V3500
Standard Container(*1) HDPE 3.5L Standard Container
Maximum Processing Amount(*2) 3.5kg×2 containers
Revolution 9 levels (9-1)
Rotation 10 levels (9-0)
(0.0-0.78 times of revolution speed)
(Limited by the level of revolution)
Setting Time 10-300 seconds × 3 steps
Number of Channel 20 (fixed channel: 10,
user setting channel:10)
Vacuum System Pump Ultimate pressure: 20Pa
Pumping speed: 49㎥/h(50Hz)、59㎥/h(60Hz)
Chamber Independent chamber with reduced pressure only in the vessel rotation area
Settings 3 mode settings
1: Keep vacuum level 1
2: Keep vacuum level 2
3: Continuous vacuum
Alarm Function Unbalance, Upper lid and /or maintenance cover open, and overload
Safety Function Automatic shutoff in case any error, locking the door while operation and preventing the system from while the door open
Temperature and Humidity for use 10-40℃, 20-80%RH (No dew condensation)
Power Supply 3φ、AC200V±10%
Power Consumption Approx.7.0kW
Monitoring Function
(*3)
-
Dimension 1095×995×1150 mm
Main Body Weight Approx.550kg(vacuum pump is not included)

 * Specifications may change without prior notice.
(*1)Multiple types of containers and syringes can be used by optional adapters.
(*2)Gross weight including container and adapter. Processing weight may be less depending on operating conditions and sample characteristics.
(*3)Temperature sensor unit is sold separately.